Probest TOC online automatic water quality monitor strictly follows the national standard of "Determination of Water Quality, Total Organic Carbon, Combustion Oxidation-Non-Dispersive Infrared Absorption Method" (HJ 501-2009). The product integrates high-precision detection, automated operation and intelligent management, which can effectively meet the monitoring needs of the whole chain from pollution source supervision to process control, and is a reliable choice to promote water environment management towards digitalization and refinement.
PCM300-TOC Total Organic Carb Quality Online Automatic Monitor
View More
The working principle of ultrasonic level gauge is that the transducer (probe) emits a high-frequency ultrasonic pulse that is reflected back when it encounters the surface of the measured medium, and is partially received by a transducer and converted into an electrical signal. The ultrasonic pulse propagates at the speed of sound waves, and the time interval from transmission to reception of the ultrasonic pulse is directly proportional to the distance on the surface of the transducer.
ULM Series Ultrasonic Level Meters
View More
The electromagnetic flowmeter works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids. The EFM30 electromagnetic converter core adopts a high-speed central processing unit, which has a very fast calculation speed. The sensor adopts non-uniform magnetic field technology and special magnetic circuit structure, which has a stable and reliable magnetic field and reliable measurement performance.
EFM30 Electromagnetic Flow Meter
View More
CL-201 is an accurate, cost-effective and low-maintenance instrument for measuring residual chlorine/total residual chlorine/reactive oxygen species in the disinfection process and monitoring of residual chlorine/total residual chlorine concentration in drinking water pipe networks using DPD colorimetric method.
CL-201 Residual Chlorine/Total Residual Chlorine/Active Oxygen Species Online Analyzer
View More
The ion selection electrode method was used to measure the ammonia nitrogen concentration. The ammonia nitrogen ion selection electrode directly detected the ammonium root ions in the water environment to determine the concentration of ammonia nitrogen. The pH electrode was used as the reference electrode to obtain better stability. Because the measurement results of the sensor are easily interfered with by potassium ions, potassium ion compensation is required when the concentration of potassium ions in the water is high.
PINH3-900 Ammonia Nitrogen Online Analyzer
View More
PFDO-800 dissolved oxygen online analyzer uses fluorescence method to measure dissolved oxygen, the top of the sensor is covered with a layer of fluorescent substance, when the blue light emitted by the sensor irradiates the fluorescent substance, the fluorescent substance is excited to emit red light, because the oxygen molecule can take away energy (quenching effect), so the time and intensity of the excited red light are inversely proportional to the concentration of oxygen molecules, and the concentration of dissolved oxygen in the water can be obtained by calculation.
PFDO-800 Fluorescence Dissolved Oxygen Online Analyzer
View More
The ultrasonic flowmeter/ultrasonic calorimeter uses the principle of low voltage and multi-pulse time difference, and adopts the high-precision and ultra-stable double-balanced signal differential transmission and differential reception patented digital detection technology to measure the transmission time of sound waves in the downstream and counterflow directions, and calculates the flow rate according to the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference.
UFM Series Ultrasonic Flowmeters
View More
The Pt series diffusion silicon pressure transmitter is a new generation of pressure transmitter produced by using imported chips, after careful structural design, signal processing and assembly, and testing in accordance with national standards and enterprise standards. The basic principle is to use the piezoresistive effect and micromachining technology of semiconductors, use lithography, diffusion and other semiconductor processes to make a Wheatstone bridge, form a sensitive diaphragm, when under the action of external force, produce microstrain, resistivity changes, so that the resistance of the bridge arm changes (one pair becomes bigger and one pair becomes smaller) and then excites the voltage signal output, through computer temperature compensation, laser resistance regulation, signal amplification and other processing methods and strict assembly testing, calibration and other processes, to produce a pressure transmitter with standard output signal.
PT Series Diffusion Silicon Pressure Transmitter
View More
PT10M immersive level transmitter selects imported high-precision and high-stability diffusion silicon pressure-sensitive chips, and converts the liquid level signal of the measured liquid into a 4-20mA DC standard signal through a high-reliability amplification circuit. High-quality sensors, exquisite packaging technology, and perfect assembly processes ensure the excellent quality and performance of this product. This product is divided into two structures: integrated and split. The product can resist the erosion of a variety of corrosive liquids and can meet the needs of customers to the greatest extent.
PT10M Diffused Silicon Input Level Transmitter
View More
PLM-800 waterproof multi-parameter measurement and control terminal is a micro-power, multi-functional, and system solution suitable for measurement and control in manhole environment that integrates data acquisition, data communication and monitoring. It adopts an integrated modular design that effectively integrates RTU wireless transmission terminal and disposable lithium sub-battery. It can optionally have built-in radar level, and can support pH, conductivity, dissolved oxygen, ammonia nitrogen, COD, turbidity, SS, liquid level, flow, and up to 6 MODBUS485 sensors to meet the needs of water quality and water level monitoring in manholes and other complex situations.
PLM-800 Waterproof Multi-Parameter Measurement and Control Terminal
View More
PADV-60 ultrasonic Doppler flowmeter is a flow meter made by using the Doppler effect principle. The measurement point is in front of the probe, which does not damage the flow field, and has the advantages of high measurement accuracy, wide range, and fast response speed. The internal integration of pressure sensor and temperature sensor integrates the measurement of flow rate, liquid level, temperature and flow. It is suitable for flow rate and flow measurement of open channels, rivers, drainage pipe networks and various full and non-full pipes.
PADV-60 Ultrasonic Doppler Flow Meter
View More
The low-power data acquisition terminal (RTU) adopts a low-power design, and its dormant power consumption is less than 50uA@DC12V, which is especially suitable for cases that require battery power or solar power, which can greatly reduce the capacity of the battery and save costs. The data transmission mode is GPRS, 4G full Netcom, and NB-10T, which are suitable for collecting various instrument output signals and realizing remote transmission.
Low-Power Data Acquisition Terminals (RTUs)
View More
Prev
1
2
...
7
Next
Customer Service Hotline
400-691-3118
Address: 4th Floor, Industrial Building, No. 170 Jinyan Road, Jianxin Town, Cangshan District, Fuzhou City, Fujian Province
Email: liuhailong@probest.cn
WeChat Official Account
Copyright © Fuzhou Probest Intelligent Technology Co., Ltd. All rights reserved | Powered by 233 Technology