中文 EN
返回
Product Center
pdcl-400
pdcl-400-
pdcl-400-1

PDCL-400 Residual Chlorine/Chlorine Dioxide Online Analyzer

The PDCL-400 residual chlorine/chlorine dioxide sensor adopts the advanced constant voltage principle to measure residual chlorine/chlorine dioxide in water. This method uses a stable potential potential applied between the polarized electrode and the reference electrode, and different components under this potential generate different current intensities. The meter calculates the concentration of the measured component through the acquisition and analysis of the current signal.
产品描述
Product Introduction

PDCL-400 residual chlorine/chlorine dioxide sensor adopts the advanced constant voltage principle to measure residual chlorine/chlorine dioxide in water. This method uses a stable potential potential applied between the polarized electrode and the reference electrode, and different components under this potential generate different current intensities. The meter calculates the concentration of the measured component through the acquisition and analysis of the current signal.
PDCL-400 residual chlorine/chlorine dioxide electrode has a simple structure, easy to clean and replace, and does not need to replace the diaphragm and reagent during the use of the electrode, and simple maintenance to ensure the stability, reliability and accuracy of the instrument for long-term operation.

Application Scenarios
  • For residual chlorine/chlorine dioxide measurement in waterworks, drinking water distribution networks, swimming pools.
  •  
技术参数
原理 恒电压法
测量范围 0-2mg/L,0-20mg/L(可选)
温度补偿 手动或自动温度补偿
温度系数 2%/℃
样品pH范围 5-8
流速要求 30-60L/h
⼯作温度 0-50℃(不结冰)
电极尺寸 13.5*178.5mm(直径*长度)
安装螺纹尺寸 PG13.5
电极材质 316不锈钢壳体
电缆长度 标配5⽶电缆,最大可延长至20⽶

 

1 / 1
Visualizações:
1000

PDCL-400 Residual Chlorine/Chlorine Dioxide Online Analyzer

The PDCL-400 residual chlorine/chlorine dioxide sensor adopts the advanced constant voltage principle to measure residual chlorine/chlorine dioxide in water. This method uses a stable potential potential applied between the polarized electrode and the reference electrode, and different components under this potential generate different current intensities. The meter calculates the concentration of the measured component through the acquisition and analysis of the current signal.
Preço de varejo
0.0
Yuan
Preço de mercado
0.0
Yuan
Visualizações:
1000
Número do produto
Quantidade
-
+
Estoque:
0
1
Descrição de produto
Product Introduction

PDCL-400 residual chlorine/chlorine dioxide sensor adopts the advanced constant voltage principle to measure residual chlorine/chlorine dioxide in water. This method uses a stable potential potential applied between the polarized electrode and the reference electrode, and different components under this potential generate different current intensities. The meter calculates the concentration of the measured component through the acquisition and analysis of the current signal.
PDCL-400 residual chlorine/chlorine dioxide electrode has a simple structure, easy to clean and replace, and does not need to replace the diaphragm and reagent during the use of the electrode, and simple maintenance to ensure the stability, reliability and accuracy of the instrument for long-term operation.

Application Scenarios
  • For residual chlorine/chlorine dioxide measurement in waterworks, drinking water distribution networks, swimming pools.
  •  
技术参数
原理 恒电压法
测量范围 0-2mg/L,0-20mg/L(可选)
温度补偿 手动或自动温度补偿
温度系数 2%/℃
样品pH范围 5-8
流速要求 30-60L/h
⼯作温度 0-50℃(不结冰)
电极尺寸 13.5*178.5mm(直径*长度)
安装螺纹尺寸 PG13.5
电极材质 316不锈钢壳体
电缆长度 标配5⽶电缆,最大可延长至20⽶

 

Related Cases